DYNAguard V DYNAInstruments

特徴

he sensor electronics units of DYNAguard V connected with process couplings of ESR series helps to monitor the mass flow in solid material handling applications such as pneumatic transport lines, feeders or gravity chutes in a wide range of mass flow from g/h to t/h. Conveying or feeding problems of powders, pellets or granules are detected early and thus should be avoided.
This helps to prevent plant failures like clogging, material loss, idle or other serious difficulties. The meter detects moving electrical charges that are produced, for example, through friction with other objects such as the pipe wall and then naturally adhere to the solids surface, solid lining will not be detected. A multitude of sensor mechanics units makes process coupling very easy and allows cost effective solutions for almost any monitoring application - also in existing conveying systems. The advantage of this modular concept also appears in case of refit or exchange. The device is not applicable for solids which build up an electrical conducting layer on the sensor through friction or deposition.

お問合せ

仕様

Flow Indicator for Solids


  • Electrostatic / triboelectric
  • Non-contact, non-intrusive
  • Electronic module without process coupling (please refer to ESR...below)
  • Multitude of couplings are available
  • Variable user
  • Revolving screw-link to the process coupling
  • Detection of only moving material - not influenced by deposits
  • Relay and 4...20mA version
  • Flow displayed by LED-bar (relay version)
  • Reliable, longterm stable, maintenance free
  • Technical Data


    Material Housing Edelstahl 1.4305 (ASIS 303)
    Screw-link Stainl. steel 1.4301 (AISI 316 Ti)
    Sealing (standard) NBR
    Ambient cond. Temperature -20 °C ... +70 °C (-4 °F ... +158 °F)
    Degree of protection IP 67 (EN 60529)
    EMC According to EN 61326-1
    Output DYNAguard V01 Relais: max. 48 V AC/DC, 1A
    High/low switchable
    DYNAguard V02 Transistor: galvanisch getrennt
    Max. 31 V DC, 15 mA
    High/low switchable
    DYNAguard V20 4 - 20 mA, galvanically isolated
    Load < 500 Ω
    Supply Voltage DYNAguard V01/V02 17 - 31 V DC, max. 60 mA
    DYNAguard V20 17 - 31 V DC, max. 90 mA
    Adjustment Sensitivity 1 - 180.000
    Damping 0 - 10 s (V01/02), 0 - 180 s (V20)
    Switchpoint 1 - 10 (DYNAguard V01/02)
    Zero set 4 mA (DYNAguard V20)


    DYNAguard S Datasheet - flow switch for bulk solids
    ESR ZF Datasheet - process coupling
    Brochure DYNAguard Series
    Product overview DYNA Instruments

    03-3730-5991 お問合せ

    購入ご検討段階から納入後のトラブル対応まで、経験豊富なスタッフが確かな技術力でお客様のご要望にお答え致します。まずは是非一度お気軽にご相談ください。

    サポート

    製品ピックアップ

    すべて

    prev next

    展示会・イベント

    詳細へ

    国内で開催される様々な展示会・イベントで製品をご覧頂けます。


    JFES

    • 製品カタログ ダウンロード
    • 製品カタログ ダウンロード
    • 製品カタログ ダウンロード
    お問い合わせ・資料請求

    Copyright© JAPAN MACHINERY Co., Ltd. All rights reserved.